安川L1000A变频器报crst故障怎么解决?

发布网友 发布时间:2022-04-20 06:41

我来回答

3个回答

懂视网 时间:2022-05-05 21:34

Oracle 11.2.0.3 1、报错信息 检查第1节点的CRS alert log,发现存在有下面异常信息 2013-0X-XX 19:27:17.609 [ctssd(18809

Oracle 11.2.0.3

相关mysql视频教程推荐:《mysql教程》

1、报错信息

检查第1节点的CRS alert log,发现存在有下面异常信息

2013-0X-XX 19:27:17.609
[ctssd(18809056)]CRS-2409:The clock on host XXXdb1 is not synchronous with the mean cluster time. No action has been taken as the Cluster Time Synchronization Service is running in observer mode.
2013-0X-XX 19:59:42.312
[ctssd(18809056)]CRS-2409:The clock on host XXXdb1 is not synchronous with the mean cluster time. No action has been taken as the Cluster Time Synchronization Service is running in observer mode.

上面报错的意思是,ORACLE的CTSSD服务发现异常,不能处于观察模式

2、报错信息问题分析

2.1、操作系统的NTPD服务处于启动状态,CTSSD就不会工作,但是只要CTSSD服务启动,正常情况下应该处于观察模式

2.2、当前OS的NTPD服务正在运行,并且,CTSSD不能处于观察模式运行

3、排查过程

3.1、检查两个节点的时间是否存在差异

XXXdb1:/u01/app/11.2.0.3/grid/log/XXXdb1$ssh XXXdb2 date
Mon Jul 15 20:30:17 GMT+08:00 2013
 
XXXdb1:/u01/app/11.2.0.3/grid/log/XXXdb1$date
Mon Jul 15 20:30:18 GMT+08:00 2013

经检查,时间不存在差异

3.2、检查OS的NTPD服务

XXXdb1:/# lssrc -ls xntpd
Program name: /usr/sbin/xntpd
Version: 3
Leap indicator: 00 (No leap second today.)
Sys peer: 10.XXX.XXX.71
Sys stratum: 2
Sys precision: -18
Debug/Tracing: DISABLED
Root distance: 0.000397
Root dispersion: 0.013458
Reference ID: 10.XXX.XXX.71
Reference time: d58e6e41.d0fca000 Mon, Jul 15 2013 20:49:05.816
Broadcast delay: 0.003906 (sec)
Auth delay: 0.000122 (sec)
System flags: bclient auth pll monitor filegen
System uptime: 30149695 (sec)
Clock stability: 0.047607 (sec)
Clock frequency: 0.000000 (sec)
Peer: 10.XXX.XXX.71
flags: (configured)(sys peer)
stratum: 1, version: 3
our mode: client, his mode: server
Subsystem Group PID Status
xntpd tcpip 4128900 active

经检查两个节点,OS层的NTPD都在运行,并且可以做时间同步

3.3、检查ctssd的运行情况

XXXdb1:/#su - grid
XXXdb1:/home/grid$ crsctl stat res ora.ctssd -init
NAME=ora.ctssd
TYPE=ora.ctss.type
TARGET=ONLINE
STATE=ONLINE on XXXdb1

经检查两个节点,CTSSD服务都已经启动

3.4、借助CRS的cluvfy工具诊断CTSS错误的原因

XXXdb1:/home/grid$cluvfy comp clocksync -n all -verbose
Verifying Clock Synchronization across the cluster nodes
Checking if Clusterware is installed on all nodes...
Check of Clusterware install passed
Checking if CTSS Resource is running on all nodes...
Check: CTSS Resource running on all nodes
Node Name Status
------------------------------------ ------------------------
XXXdb2 passed
XXXdb1 passed
Result: CTSS resource check passed
Querying CTSS for time offset on all nodes...
Result: Query of CTSS for time offset passed
Check CTSS state started...
Check: CTSS state
Node Name State
------------------------------------ ------------------------
XXXdb2 Observer
XXXdb1 Observer
CTSS is in Observer state. Switching over to clock synchronization checks using NTP
Starting Clock synchronization checks using Network Time Protocol(NTP)...
NTP Configuration file check started...
The NTP configuration file "/etc/ntp.conf" is available on all nodes
NTP Configuration file check passed
……
Checking NTP daemon command line for slewing option "-x"
Check: NTP daemon command line
Node Name Slewing Option Set?
------------------------------------ ------------------------
XXXdb2 no
XXXdb1 no
Result:
NTP daemon slewing option check failed on some nodes
PRVF-5436 : The NTP daemon running on one or more nodes lacks the slewing option "-x"
Result: Clock synchronization check using Network Time Protocol(NTP) failed

见上面标红色字体部分,在做NTP slewingoption时,两个节点都不通过,原因为,NTP没有运行在“-X”模式

3.5、检查OS层NTPD的配置

(1)检查/etc/ntpd.conf

server 10.XXX.XXX.71
broadcastclient
driftfile /etc/ntp.drift
tracefile /etc/ntp.trace

(2)检查/etc/rc.tcpip文件的配置

存在有下面信息:

# Start up Network Time Protocol (NTP) daemon
start /usr/sbin/xntpd "$src_running" -a "-x"

看来配置不存在问题,但当前运行却不处于”-x”模式,很有可能是NTPD被重启过,启动时没有加上个”-x”参数

热心网友 时间:2022-05-05 18:42

你好!
安川L1000A变频器是电梯专用变频。报crst故障:有运行指令时,输入了复位信号。检查运一下外部控制线路、参数复位后重新输入参数。
SE3是顺控不良3,运行中检出空载电流25%以下的输出电流。检查一下电磁接触器有没有吸和。还不行的请找当地的安川变频器代理商或是您购买电梯的厂家。也可以去杭州奥圣电气修,他们有专业的维修人员。
仅代表个人观点,不喜勿喷,谢谢。

热心网友 时间:2022-05-05 20:00

安川L1000A变频器是电梯专用变频。报crst故障:有运行指令时,输入了复位信号。检查运一下外部控制线路、参数复位后重新输入参数。
SE3是顺控不良3,运行中检出空载电流25%以下的输出电流。检查一下电磁接触器有没有吸和。还不行的请找当地的安川变频器代理商或是购买电梯的厂家。
声明:本网页内容为用户发布,旨在传播知识,不代表本网认同其观点,若有侵权等问题请及时与本网联系,我们将在第一时间删除处理。